ITV Commercial Ice Machines
ITV commercial ice machines make every kind of ice a business uses, from 77 to 2,860 lb a day. Pick Delta NG for gourmet cocktail cubes, Spika NG for full or half dice cubes under a counter, a Spika MS or remote Spika MS R head on a bin for a busy kitchen, or Ice Queen for nugget, flake and granular ice. Every ITV machine carries 3 years parts and labor on the whole machine.
Filters
ITV RC-15 Remote Condensing Unit for Spika MS 1500 R
The ITV RC-15 is the remote condensing unit for the ITV Spika MS 1500 R ice machine head. It mounts outside or on the roof and carries the heat of ...
View full detailsITV RC-5 Remote Condensing Unit for Spika MS 500 R
The ITV RC-5 is the remote condensing unit for the ITV Spika MS 500 R ice machine head. It mounts outside or on the roof and carries the heat of ic...
View full detailsITV Ice Bucket Set (6) for EC-250 Easy Cart
A set of six ice buckets from ITV for carrying ice out of the EC-250 Easy Cart.At a Glance Set of 6 buckets Fits: ITV EC-250 Easy Cart, used with S...
View full detailsITV EC-250 Easy Cart Mobile Ice Cart, 247 lb Capacity
The ITV EC-250 Easy Cart is the polyethylene ice cart used with ITV's SCS and SCD bin systems. It holds up to 247 lb.At a Glance Capacity: 247 lb B...
View full details
ITV Commercial Ice Machines
ITV makes ice machines for almost every kind of ice a business uses: gourmet cubes for cocktails, full and half dice cubes for drinks, nugget ice for fountain drinks and healthcare, and flake and granular ice for food displays. The lineup runs from a 77 lb undercounter gourmet machine to 2,860 lb Ice Queen heads, plus bins, ice carts and hotel dispensers. This guide covers each ITV line, how to pick the ice and the size, which bin goes with which head, and what the install needs. For general sizing and ice types across every brand we carry, see our commercial ice machine buying guide.
Which ITV Line Do You Need?
Start with the ice, then the space. Each ITV line makes one family of ice in one style of cabinet.
| Line | Ice | Style | Ice per day | Good for |
|---|---|---|---|---|
| Delta NG | Gourmet cubes | Undercounter, built-in bin | 77 to 143 lb | Cocktail bars, restaurants, front of house |
| Spika NG | Full or half dice cubes | Undercounter, built-in bin | 134 to 340 lb | Bars, cafés, small kitchens |
| Spika MS | Full or half dice cubes | Modular head, 22", 30" or 48" | 423 to 1,811 lb | Restaurants, hotels, banquet kitchens |
| Spika MS R | Full or half dice cubes | Modular head with remote condenser | 441 to 2,042 lb | Hot rooms, tight spaces, guest areas |
| Ice Queen IQN | Nugget | Self-contained or 22" modular | 192 to 1,197 lb | Fountain drinks, smoothies, healthcare |
| Ice Queen IQF | Flake | 22" modular head | 772 to 1,250 lb | Seafood, meat, deli and grocery displays |
| Ice Queen IQ | Dry or wet granular | Self-contained, modular or remote | 220 to 2,860 lb | Displays, buffets, bar wells, hospitals |
Choosing the Right Ice
- Gourmet cubes: thick, clear cubes about 1.57" across and 1.73" tall. They melt slowly, so they suit cocktails, whiskey and premium soft drinks where the ice is part of the presentation.
- Full dice cubes: a classic cube that melts slower than half dice and holds up well in a bag or a cooler.
- Half dice cubes: a smaller cube that packs a glass tighter and cools a drink faster. It is the most common restaurant and fountain drink ice. Every Spika NG and Spika MS machine makes full or half dice, and you choose when you order.
- Nugget ice: small, soft and chewable, also called pebble or pellet ice. It soaks up the flavor of a drink, packs a cup well and is easy on blenders and dispensers. Restaurants, healthcare and convenience stores use it for fountain drinks and patient care.
- Flake ice: thin and soft. It molds around food without bruising it, so it goes under seafood, produce and deli displays, and it chills product quickly.
- Dry granular ice: about 20% residual water, so it stays loose and scoops easily. Use it for display cases, blended drinks and bar wells.
- Wet granular ice: soft and moldable, with more water in it. It packs around food and bottles, so it is the ice for seafood and produce displays, salad bars, buffets and cold wells. It chills quickly, which is why hospitals and labs use it.
Cubers like the Spika and Delta NG freeze water on an evaporator plate and release it in batches. Ice Queen machines use an auger that scrapes ice off a frozen cylinder, so they make soft ice continuously.
Delta NG Undercounter Gourmet Ice Machines
Delta NG machines make and store gourmet cubes in a single cabinet. They breathe through the front, so ITV designs them to fit under a bar or counter, and they plug into a standard 115V outlet. They are the smallest machines ITV makes, which suits a bar that wants premium ice right at the station.
| Model | 70°F air / 50°F water | 90°F air / 70°F water | Built-in bin | Cubes per cycle | Width |
|---|---|---|---|---|---|
| Delta NG 80 | 77 lb | 64 lb | 33 lb | 18 | 15.95" |
| Delta NG 120 | 108 lb | 95 lb | 44 lb | 24 | 21.06" |
| Delta NG 150 | 143 lb | 130 lb | 55 lb | 36 | 21.06" |
Spika NG Undercounter Ice Machines
Spika NG machines make full or half dice cubes in an undercounter cabinet on a four-column stainless frame with a stainless door. They vent through the front, so they can sit under a counter. A cleaning switch circulates descaler without running the refrigeration, and ITV's seal-less pump is made to hold up in hard water. All four run on 115V with a NEMA 5-15P plug.
| Model | 70°F air / 50°F water | 90°F air / 70°F water | Built-in bin | Width |
|---|---|---|---|---|
| Spika NG 130 | 134 lb | 103 lb | 44 lb | 21.07" |
| Spika NG 160 | 159 lb | 117 lb | 44 lb | 21.07" |
| Spika NG 230 | 223 lb | 157 lb | 77 lb | 25.99" |
| Spika NG 360 | 340 lb | 273 lb | 99 lb | 30" |
The built-in bin is the limit to plan around. A Spika NG 360 makes up to 340 lb a day but holds 99 lb at a time, so it works best where ice is scooped steadily through the day. If you need a large stockpile before a rush, a modular head on a bin holds more.
Spika MS Modular Ice Machines
A Spika MS head is just the ice maker. It drops full or half dice cubes into a bin you buy separately, so you can match how much ice you make with how much you keep on hand, and replace one later without the other. Spika MS heads use a vertical plate evaporator and a water distributor ITV designed to release ice cleanly. Every panel comes off with a screwdriver for service, and the control board flags faults so a tech can find them faster. The 22" heads fit tight spaces.
| Model | Width | 70°F air / 50°F water | 90°F air / 70°F water | Power |
|---|---|---|---|---|
| Spika MS 400-22 | 22" | 423 lb | 351 lb | 115V |
| Spika MS 500 | 30" | 518 lb | 423 lb | 115V |
| Spika MS 700-22 | 22" | 705 lb | 606 lb | 115V |
| Spika MS 1000 | 30" | 1,003 lb | 858 lb | 208-230V |
| Spika MS 1500 | 48" | 1,466 lb | 1,199 lb | 220V |
| Spika MS 1800 | 48" | 1,811 lb | 1,499 lb | 220V |
The Spika MS 700-22 is worth a look if space is tight: it makes up to 705 lb a day in a 22" head on 115V, so it fits where a 30" machine won't and doesn't need a 208-230V circuit.
Spika MS R Remote Ice Machines
A remote ice machine is three pieces: the head that makes ice, a bin under it, and a condensing unit outside or on the roof. Refrigeration lines run between the condenser and the head, so the heat and fan noise the head would put into the room go outside instead. That helps in hot kitchens, small spaces and bars where guests sit close by. Remote heads also hold their output better on a hot day, because the condenser isn't fighting the room's heat. Each head pairs with its own ITV condensing unit, sold separately, and the install needs a refrigeration tech for the line set.
| Head | 70°F air / 50°F water | 90°F air / 70°F water | Power | Condensing unit |
|---|---|---|---|---|
| Spika MS 500 R | 441 lb | 397 lb | 115V | RC-5 |
| Spika MS 1000 R | 1,041 lb | 1,006 lb | 208V | RC-10 |
| Spika MS 1500 R | 1,698 lb | 1,576 lb | 208V | RC-15 |
| Spika MS 2100 R | 2,042 lb | 1,914 lb | 220V | RC-20 |
Ice Queen Nugget, Flake and Granular Ice Machines
Ice Queen machines use an auger instead of a cube evaporator. The IQN 200C, IQ 200C and IQ 300C are self-contained with a built-in bin. The rest are heads that sit on a separate bin, and the IQ 1300R and IQ 2700R are remote (split) versions with the condenser outside, not included.
| Model | Ice | Style | 70°F air / 50°F water | 90°F air / 70°F water | Power |
|---|---|---|---|---|---|
| IQN 200C | Nugget | Self-contained, 44 lb bin | 192 lb | 159 lb | 115V |
| IQN 700 | Nugget | 22" modular | 714 lb | 579 lb | 115V |
| IQN 900 | Nugget | 22" modular | 860 lb | 664 lb | 115V |
| IQN 1200 | Nugget | 22" modular | 1,197 lb | 895 lb | 220V |
| IQF 700 | Flake | 22" modular | 772 lb | 635 lb | 115V |
| IQF 900 | Flake | 22" modular | 925 lb | Not listed | 115V |
| IQF 1200 | Flake | 22" modular | 1,250 lb | 930 lb | 220V |
| IQ 200C | Dry granular | Self-contained, 44 lb bin | 220 lb | 140 lb | 115V |
| IQ 300C | Dry granular | Self-contained, 88 lb bin | 360 lb | 260 lb | 115V |
| IQ 900 | Wet granular | Modular | 980 lb | 710 lb | 208-230V, 1-phase |
| IQ 1300 | Wet granular | Modular | 1,430 lb | 1,030 lb | 208-230V, 1-phase |
| IQ 1300R | Wet granular | Remote (split) | 1,430 lb | 1,030 lb | 208-230V, 3-phase |
| IQ 2700 | Wet granular | Modular | 2,860 lb | 2,060 lb | 208-230V, 3-phase |
| IQ 2700R | Wet granular | Remote (split) | 2,860 lb | 2,060 lb | 208-230V, 3-phase |
The IQ 200C, IQ 300C, IQ 900, IQ 1300 and IQ 2700 also come water-cooled; choose it in the Cooling option on the product page. Water-cooled machines put less heat into the room but use more water. The table shows the air-cooled ratings.
How to Size an ITV Ice Machine
Size the machine to your busiest day, not your average one, and use the 90°F air / 70°F water number if your kitchen runs hot. ITV publishes how much ice different businesses use. A few of its figures:
- Traditional bar: 0.22 lb per customer
- Standard restaurant: 0.33 lb per customer
- Full-service restaurant or night club: 0.66 lb per customer
- Seafood restaurant: 1.1 lb per customer for drinks, plus 2.75 lb per customer for display ice
- Hotel: 0.66 lb per room
- Hospital: 0.66 lb per patient
Multiply your busiest day's count by the figure, add anything people forget, like to-go cups, catering and chilling product, then leave 10 to 20% headroom. For the full list, see How Much Ice Do I Need?
Cocktail bar: 300 guests on a Saturday at 0.22 lb is about 66 lb, or about 80 lb with headroom. A Delta NG 120 makes 95 lb at 90°F/70°F, which covers it with gourmet cubes.
Hospital wing: 400 patients at 0.66 lb is about 264 lb, or about 320 lb with headroom. Patient care usually means nugget ice, and an IQN 700 makes 579 lb at 90°F/70°F, with room to serve staff and visitors too.
Seafood restaurant: 200 guests need about 220 lb of drink ice and 550 lb of display ice. That is two jobs and two machines: a Spika NG 360 covers the drinks at 273 lb on a hot day, and an IQF 1200 covers the display at 930 lb with flake ice that won't bruise the fish.
ITV Ice Bins and Which Heads Fit
Every modular head needs storage. Size the bin to hold at least half a day of ice, and use the AHRI rating, which is the industry-standard usable storage, not the full capacity. The S-500, for example, holds 510 lb full and 408 lb AHRI.
| Bin | Holds | AHRI rating | Width | ITV lists it for |
|---|---|---|---|---|
| S-300 | 353 lb | 282 lb | 30" | Spika MS 400-22, MS 500, MS 700-22 and MS 1000; IQ 900, IQ 1300 and IQ 1300R |
| S-400-22 | 400 lb | 320 lb | 22" | Spika MS 700-22; the 22" IQF and IQN heads |
| S-500 | 510 lb | 408 lb | 30" | Spika MS 500, MS 700-22 and MS 1000; IQ 900, IQ 1300 and IQ 1300R; IQF and IQN |
| S-750 | 750 lb | 600 lb | 42" | Spika MS 500, MS 700-22 and MS 1000; IQ 900, IQ 1300, IQ 1300R and IQ 2700R; IQF and IQN |
| S-900 | 860 lb | 688 lb | 48" | Spika MS 500, MS 700-22 and MS 1000; IQ 900, IQ 1300, IQ 1300R and IQ 2700R; IQF and IQN |
| S-1050 | 1,058 lb | 846 lb | 52" | Spika MS 500 and MS 1000, one or two side by side; IQ 900, IQ 1300, IQ 1300R, IQ 2700 and IQ 2700R; IQF and IQN |
The 48" Spika MS 1500 and MS 1800 need a bin at least that wide, such as the 52" S-1050 or a 60" cart system like the SCD-1400. The 22" heads also sit on wider bins, so you can put a small head on a big bin and build up storage. Each head's product page lists the bins ITV pairs with it. All S-series bins have 304 stainless steel fronts and sides, a seamless polyethylene liner with rounded corners, built-in drainage, 6" adjustable legs and a scoop.
Ice Carts and Hotel Dispensers
Bins with carts are for hotels, hospitals, stadiums, caterers and food plants that move a lot of ice between rooms. The ice drops into carts that each hold up to 247 lb and roll out with brakes, a drain and a cover.
| Cart system | Holds | Carts | Width |
|---|---|---|---|
| SCS-350 | 309 lb (243 lb AHRI) | 1 | 30" |
| SCS-700 | 661 lb (529 lb AHRI) | 1 | 30" |
| SCD-900 | 911 lb (AHRI-certified) | 2 | 60" |
| SCD-1400 | 1,360 lb (AHRI-certified) | 2 | 60" |
| SCD-1800 | 1,790 lb (AHRI-certified) | 2 | 60" |
Extra carts are sold as the EC-250 Easy Cart, which holds 247 lb, and the bucket set fits it for quick distribution. The IBK-1 bagger kit lets you bag ice straight from a bin.
For self-serve ice, the DHD hotel dispensers let guests fill a bucket or cup without touching the ice, and the head on top keeps them topped up. Both sizes dispense about 0.24 lb per second, and the -W versions add water. The DHD 130-22 and DHD 130-22-W store 128 lb in a 22" cabinet and take the Spika MS 700-22. The DHD 200-30 and DHD 200-30-W store 183 lb in a 30" cabinet and take the Spika MS 500 or MS 1000. The inside bin opens for cleaning without moving the ice machine.
Before You Order an ITV Ice Machine
- Power: every Delta NG and Spika NG, the Spika MS 400-22, MS 500, MS 700-22 and MS 500 R, the IQN 200C, IQN 700, IQN 900, IQF 700, IQF 900, IQ 200C and IQ 300C run on 115V. The rest need 208-230V, and the IQ 1300R, IQ 2700 and IQ 2700R need 3-phase power, which many small buildings don't have. Have an electrician confirm the circuit before delivery.
- Water: a cold potable water line. ITV recommends a water filter to control scale and chlorine.
- Drain: a floor drain or floor sink. Ice machines drain by gravity, so the drain must sit below the machine's drain outlet.
- Space and airflow: measure the head plus the bin, and leave room above and around the head for airflow and service. Undercounter Delta NG and Spika NG machines vent through the front, so they can sit under a counter.
- Remote systems: plan a spot outdoors or on the roof with open airflow around the condenser coil, and a refrigeration tech to run the line set.
- Bin: modular heads ship without a bin. Order the bin with the head so they ship together.
- Install: we don't offer installation. A plumber or refrigeration tech can set it up.
Water Filters for ITV Ice Machines
ITV lists a water filter on every machine's spec sheet, and each product page names the match. A filter cuts scale and keeps warranty work down.
- PRO-101K: Delta NG, Spika NG and Ice Queen machines. Uses the PRO-10 cartridge.
- PRO-102K: Spika MS 400-22, MS 500, MS 700-22, MS 1500 and MS 1800. Uses PRO-10 cartridges.
- PRO-112K: Spika MS 1000 and MS 1000 R. Uses the PRO-11 cartridge.
- CF-250 MAX: Spika MS 2100 R.
See every system and cartridge in ice machine water filters.
Cleaning and Care
Scale and slime are what slow an ice machine down. Change the filter cartridge on schedule, descale and sanitize the machine and bin as ITV's manual directs, and keep the condenser and air path clean so the machine can breathe. On the Spika NG, the cleaning switch circulates descaler without running the refrigeration. Throw out any ice made during cleaning.
ITV Warranty
- Spika and Delta NG cubers: 3 years parts and labor on the whole machine, 5 years parts and labor on the evaporator, and 5 years parts with 3 years labor on the compressor.
- Ice Queen nugget, flake and granular machines: 3 years parts and labor on the whole machine, with 5 years parts and 3 years labor on the auger and the compressor.
- Bins, ice carts and dispensers: 3 years parts and labor.
ITV Ice Machine FAQ
Do ITV modular heads come with a bin?
No. Spika MS, Spika MS R, IQ 900 and larger, IQF and IQN modular heads sit on a separate bin. The IQN 200C, IQ 200C and IQ 300C have a built-in bin.
Can I choose full dice or half dice?
Yes, on every Spika NG and Spika MS machine. You pick the cube size when you order.
Does ITV make nugget ice machines?
Yes. The Ice Queen IQN 200C makes 192 lb a day with a built-in bin, and the IQN 700, IQN 900 and IQN 1200 heads make 714 to 1,197 lb a day.
What's the difference between flake and granular ice?
Flake ice is thin and soft. Granular ice is small pieces that are either dry, which scoop easily, or wet, which pack around food and hold cold longer.
What refrigerant do ITV machines use?
ITV lists R290, a natural refrigerant, on its Delta NG, Spika NG, Spika MS and several Ice Queen models. Check the product page for your model.
Are any ITV machines water-cooled?
The IQ 200C, IQ 300C, IQ 900, IQ 1300 and IQ 2700 come air-cooled or water-cooled. Everything else is air-cooled or remote.
Is ITV a good alternative to Manitowoc or Hoshizaki?
Yes. ITV makes the same ice types, including cube, gourmet, nugget, flake and granular, and carries 3 years parts and labor on the whole machine.
Do you install ITV ice machines?
No. A plumber or refrigeration tech can install it. Remote systems need a refrigeration tech for the line set.